Skip to main content
Conference Proceedings

1994 AuslMM Annual Conference, Darwin, August 1994

Conference Proceedings

1994 AuslMM Annual Conference, Darwin, August 1994

PDF Add to cart

Accelerated Cyanidation Assays Using LeachWELL 60X - The Bannockburn Experience

A testwork program aimed to improve the assaying of underground face
samples established that for an Accelerated Cyanidation Extraction using
the LeachWELLTM 60X catalyst, followed by an Aqua Regia finish (to
quantify non-cyanide-extractable gold): Assay results (including the aqua regia finish) from a full set of
samples from one underground face can be returned within four
hours. The reagent dose to make the method simple and 'bullet-proof' is
8 gm LeachWELLTM 60X and 20 gm NaCN per 200 gm sample
(30 per cent solids). Pulverising is to 90 per cent passing 75
micron (compared to the standard of 90 per cent passing 150
micron), and cyanidation is completed within one hour - however both might be further optimised. The LeachWELLTM/Aqua Regia results demonstrate that Fire
Assays suffer from a significant nugget effect which makes the
Fire Assay data relatively unreliable. Original costs, specific to Bannockburn (viz including an Aqua
Regia finish), handling approximately 20 000 to 25 000 per annum
is estimated to be $5.40, ie about one-third less than fire assaying.
Optimising is further reducing these costs. It is estimated that the LeachWELLT"'/Aqua Regia assay procedure has
reduced the probable error limits of any given assay of this ore from the
range 0.74x to 1.36x for Fire Assay, to an appreciably smaller range of
0.90x to 1.11x. Thus for a cut-off grade of 1.60 g Au/t, samples with Fire Assays
ranging up to 2.18 g Au/t have 25 per cent chance of being below cut-off,
while samples with Fire Assays as low as 1.18 g Au/t have an equal
chance of actually exceeding cut-off grade. This 1 g Au/t range in
uncertainty is generally unacceptable for many practicalgrade/tonnage
relationships. By contrast, using LeachWELLTM + Aqua Regia assays, the estimated
corresponding limits are 1.44 g Au/t and 1.78 g Auk respectively - a far
more tolerable 0.34 g Au/t range of uncertainty. Subsequent data has demonstrated that sufficient accuracy for grade
control is achieved by Accelerated Cyanidation alone, further halving the
cost of assays.
Return to parent product
  • Accelerated Cyanidation Assays Using LeachWELL 60X - The Bannockburn Experience
    PDF
    This product is exclusive to Digital library subscription
  • Accelerated Cyanidation Assays Using LeachWELL 60X - The Bannockburn Experience
    PDF
    Normal price $22.00
    Member price from $0.00
    Add to cart

    Fees above are GST inclusive

PD Hours
Approved activity
  • Published: 1993
  • PDF Size: 0.219 Mb.
  • Unique ID: P199405006

Our site uses cookies

We use these to improve your browser experience. By continuing to use the website you agree to the use of cookies.