Conference Proceedings
Sixth International Conference on Acid Rock Drainage (ICARD)
Conference Proceedings
Sixth International Conference on Acid Rock Drainage (ICARD)
Field Performance of Dry Covers and Limestone Addition for Acid Generation Control of Lavrion Sulfide Tailings, Greece
Acid generating sulfidic tailings covering a surface area of approximately ten hectares have been deposited in the historic mining area of Lavrion in Greece. For the development of a remediation strategy, the performance of three alternative acid generation control techniques was assessed under actual field conditions. The techniques involved the application of dry covers, including a synthetic HDPE liner and a compacted clay layer with capillary barriers. Furthermore, the potential formation of a low permeability hardpan layer at the sulfidic tailings surface by limestone addition was investigated. The field tests covered an area of 2500 m2, which was divided in equal quadrants, corresponding to the control plot and the three alternative remedial options. To monitor the amount and quality of percolated water, lysimeters were installed beneath the four plot areas. Based on the monitoring results over a period of six years, due to the dry climate encountered in the Lavrion area, a low amount of water percolates through the pyrites if no action is taken (control area), corresponding to 20 - 25 mm per year. This water is highly acidic, pH = 1.2, and contains a heavy load of contaminants, eg Fe 40 g/L, Zn 15 g/L, and As 1.5 g/L. The HDPE cover eliminated the percolation of water into the material for a period of five years, whereas thereafter the volume of leachates increased to values similar to those recorded in the control plot. The water collected in the lysimeter of the clay cover has been minimal corresponding to approximately five per cent of the drainage volume produced in the control area. In the fourth plot, which involved limestone addition to sulfidic tailings, the volume of drainage initially collected was almost double compared to the control area. After three years of monitoring, significant reduction in the amount of percolated water was observed, attributed to the formation of a cemented layer (hardpan), at a depth of 40-80 cm from the testpad surface.
Contributor(s):
E Mylona, N Papassiopi, A Xenidis, I Paspaliaris
-
Field Performance of Dry Covers and Limestone Addition for Acid Generation Control of Lavrion Sulfide Tailings, GreecePDFThis product is exclusive to Digital library subscription
-
Field Performance of Dry Covers and Limestone Addition for Acid Generation Control of Lavrion Sulfide Tailings, GreecePDFNormal price $22.00Member price from $0.00
Fees above are GST inclusive
PD Hours
Approved activity
- Published: 2002
- PDF Size: 0.468 Mb.
- Unique ID: P200303089