Conference Proceedings
Sixth International Conference on Acid Rock Drainage (ICARD)
Conference Proceedings
Sixth International Conference on Acid Rock Drainage (ICARD)
Performance of Shallow Water Covers on Pyritic Uranium Tailings
The performance of in situ, shallow water covers in controlling acid generation was evaluated at four recently decommissioned pyritic uranium tailings sites at Elliot Lake, Ontario, Canada. The tailings are acid generating, having a pyrite content of approximately five to ten per cent and a very low to non-existent alkaline buffering capacity. Adverse market conditions led to the closure of all operating uranium mines in the early- to mid-1990s, followed by rehabilitation and decommissioning of mine and waste management facilities._x000D_
In order to control acidic drainage, all new and active tailings areas at Denison, Quirke, Panel, Spanish-American and Stanleigh mine sites were re-engineered to provide in situ submersion of these tailings under shallow water covers. The tailings impoundment dams were upgraded and reinforced or in some cases reconstructed, to minimise seepages and provide a minimum 1 m depth of water cover._x000D_
With the exception of Stanleigh mine, which was closed in 1996 and rehabilitated during the late-1990s, the water covered Tailings Management Areas (TMAs) at other sites have been in operation for a period of six to nine years. The surface water quality at these sites is maintained at near neutral pH conditions by periodic addition of lime slurry to the established water covers._x000D_
Additional treatment of effluent is provided as required to meet the discharge water quality standards. The performance of the established water covers at the sites was evaluated by analysing the annual equivalent limestone consumption data. The results were compared with the performance of an older, decommissioned Nordic TMA, which was rehabilitated using revegetation techniques. The water covers at these sites are performing as designed and acid generation has been reduced to low levels._x000D_
Based on the total amount of yearly equivalent limestone required to maintain water quality in the water cover and at the effluent treatment plant, it is concluded that acid generation rate at the Denison TMA has reduced to less than 0.15 per cent of its pre-water cover conditions during normal operation and rehabilitation periods. In comparison to the revegetated Nordic TMA, the acid generation rates at Denison and Panel TMAs have decreased to less than 1.6 per cent of that at the Nordic TMA. The acid generation rate at the Quirke TMA was comparable or only slightly lower than that at the Nordic TMA because of its unique terraced cell configuration, having tailings in five hydraulically interconnected cells at different elevations._x000D_
Historic acidity and oxidation reaction products, accumulated during normal operating and pre-water cover periods, are flushing from upstream locations to downstream cells, thus requiring much higher equivalent limestone additions for acid neutralisation and effluent treatment.
In order to control acidic drainage, all new and active tailings areas at Denison, Quirke, Panel, Spanish-American and Stanleigh mine sites were re-engineered to provide in situ submersion of these tailings under shallow water covers. The tailings impoundment dams were upgraded and reinforced or in some cases reconstructed, to minimise seepages and provide a minimum 1 m depth of water cover._x000D_
With the exception of Stanleigh mine, which was closed in 1996 and rehabilitated during the late-1990s, the water covered Tailings Management Areas (TMAs) at other sites have been in operation for a period of six to nine years. The surface water quality at these sites is maintained at near neutral pH conditions by periodic addition of lime slurry to the established water covers._x000D_
Additional treatment of effluent is provided as required to meet the discharge water quality standards. The performance of the established water covers at the sites was evaluated by analysing the annual equivalent limestone consumption data. The results were compared with the performance of an older, decommissioned Nordic TMA, which was rehabilitated using revegetation techniques. The water covers at these sites are performing as designed and acid generation has been reduced to low levels._x000D_
Based on the total amount of yearly equivalent limestone required to maintain water quality in the water cover and at the effluent treatment plant, it is concluded that acid generation rate at the Denison TMA has reduced to less than 0.15 per cent of its pre-water cover conditions during normal operation and rehabilitation periods. In comparison to the revegetated Nordic TMA, the acid generation rates at Denison and Panel TMAs have decreased to less than 1.6 per cent of that at the Nordic TMA. The acid generation rate at the Quirke TMA was comparable or only slightly lower than that at the Nordic TMA because of its unique terraced cell configuration, having tailings in five hydraulically interconnected cells at different elevations._x000D_
Historic acidity and oxidation reaction products, accumulated during normal operating and pre-water cover periods, are flushing from upstream locations to downstream cells, thus requiring much higher equivalent limestone additions for acid neutralisation and effluent treatment.
Contributor(s):
I Ludgate, A Coggan, N K Dave
-
Performance of Shallow Water Covers on Pyritic Uranium TailingsPDFThis product is exclusive to Digital library subscription
-
Performance of Shallow Water Covers on Pyritic Uranium TailingsPDFNormal price $22.00Member price from $0.00
Fees above are GST inclusive
PD Hours
Approved activity
- Published: 2002
- PDF Size: 2.359 Mb.
- Unique ID: P200303092