Autocompression and virgin rock tempera ture have a marked influence on the ventilation of the lower levels at North Broken Hill Limited N.S.W. To maintain comfortable working temp- eratures without penalty to working hours, increase in airflow or the cooling of the work area is necessary. The use of refrigerated air cooling is discussed. Ventilation of underground mining opera tions at North Broken Hill Limited is accomplished by downcasting air through No.3 shaft, the main operating shaft, 1581 m deep, with additional air through No.1 shaft (542 m) 2 and No.2 shaft (978 m), both no longer opera- tional shafts. Air is upcasted through No.3 ventilation shaft which is 4.9 m diameter and concrete lined, from the No.28 level (1140 m) to the surface. On the surface level of this shaft is a horizontally mounted Richardson 4800 mm diameter single stage axial flow fan with adjustable pitch rotor blades.